DCM 200 Installation
Page 30
Relay & Frequency Controls Comparison (cont.)
Notes
1.
Contact Sets
Runs once per controlling contact closure.
In addition to being able to use Contact sets to turn ON & OFF relays and frequency
controls, contact sets can have the following compensation:
Invert ON/OFF:
Switches the logical sense of the contact set so you can control on contacts opening or
closing.
Applications: Allows a control only when relay changes state
Surge tank fill, remote disable, second flow switch
2.
Feed Limits
Users may set OFF on Alarm, turning OFF a Relay or Frequency on a time limit.
6.7. System Alarms & Indicating LEDs
System Alarms
Alarms are not specific to any sensor or control.
Name
Alarm Message & Ca
use
Effect
1
2
VDC External
Low Alarm
Wiring errors or a fault on any sensor
powered by the controller 12VDC
‘DC Power Output’ supply
Correct wiring. Remove defective sensor.
12VDC thermal fuse auto-recovers.
While alarmed: sensors, meters and current loops
powered by the 12VDC supply will not operate.
Internal 2.5V
Out of Range
Sensor, meter or contact set wiring
error
Used to auto-calibrate all sensor measurements to
remove power supply drift error.
All sensor measurements stop auto-calibration.
Indicating LEDs
Name
Location
Function
Blue
‘OK’
Facepanel to right of LCD
Screen
On when there are no Alarms
Flashes when flow switch is OFF or recovering
Red
‘ALARM’
Facepanel to right of LCD
Screen
Flashes when any alarms are active.
Green
‘LINK’
Bottom left of Ethernet jack
On steady with Ehternet connected
Green
‘ACTIVE’
Bottom Richt of Ethernet
jack
Flashes with Ethernet activity
Green
P1, P2, R3
Lower Right Main board
Above Neutral Terminal #4
ON whenever the Relay is ON.
Red
D5,D9
Lower Edge of Main PCB
Above Relay 4 & 5
24V CONTACTS terminals
ON when contact is closed or ON for 50% of the pump
frequency period. Mirrors the time that the electronic contact set
pulsing the pump is closed. Example: A pump running at 10
SPM would have it’s indicating LED on for 3 Seconds and OFF
3 Seconds since 10 Strokes/Minute is a 6 second period & 5.5%
of rated for a 180SPM rated pump.
LCD
Backlight
Behind LCD Display ON when the controller is AC powered and its internal 5VDC
supply is @ 5VDC.