DCM 200 Installation
Page 16
CAUTION
BASIC SAFETY PRACTICES AND MOST LOCAL ELECTRICAL CODES
REQUIRE THIS CONTROLLER’S ELECTRICAL POWER TO BE
PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
2.3.1. 120VAC Line Power and Feeder Wiring
The factory pre-wired your controller with a power cord and two 120VAC receptacle cords, unless you
requested otherwise. For conduit wiring configurations, remove the cords supplied and replace the
cord wiring with the individual wires from the conduit. The same terminals are used and are shown in
the diagram below for reference.
NEVER CONNECT FEEDER DIRECTLY TO POWER SOURCE
If the chemical feeders are connected to a wall outlet, the safety
devices integral to your ProMinent controller, and to the safe
feeding of chemicals, will be bypassed. It is very important that
the chemical feeders be connected to the controller and never
directly to a wall outlet. If the chemical feeders are connected to a
wall outlet and feeding continuously, when the flow of water to the
pool stops due to filter backwash, the circulation pump losing
prime or other causes, potentially hazardous concentrations of
chemicals can be fed into a pool or spa. Follow Instructions
carefully to insure safe operation.