GasAlertMax
User Manual
Activating the Detector
Note
The detector must be activated before entering a
potentially explosive area.
To activate the detector, press F in a normal atmosphere
(20.9% oxygen).
Self-Test
Once the detector is activated, it performs the following
checks. Manually check that all actions occur.
1. If the battery is low, I LOW flashes and the LCD
reads OFF. Replace the battery and restart the
detector.
2. The LCD displays all the elements.
3. The audible alarm beeps, the visual alarm flashes,
and the backlight briefly turns on.
Note
Steps #4 and #5 are for datalogger models only.
4. The detector tests the data card.
Note
The MultiMediaCard (MMC) icon (
S
) is displayed
continuously on black box datalogger detectors and
when a card is present in user downloadable
datalogger detectors.
Datalogger operation is automatic and requires no
settings.
Black Box Datalogger
The FAIL, ALARM, and
S
icons blink if the card
malfunctions or is removed.