Service center of POWTRAN technology company My future ,drive and control Quick guide of PI9000 operation 1.The introduction of new generation of PI9
Service center of POWTRAN technology company My future ,drive and control 6.Trial operation follow chart Trail operation Control mode Selection (F0
Service center of POWTRAN technology company My future ,drive and control 7.Wiring Of PI9000 inverter
Service center of POWTRAN technology company My future ,drive and control . Main terminal Main circuit terminal(<7.5KW, 380V): Input power Suppl
Service center of POWTRAN technology company My future ,drive and control The main terminal of 45~220kW380Vinverter Power Supply input DC reactor
Service center of POWTRAN technology company My future ,drive and control I/O control terminal of PI9000. There are two type of controller board of
Service center of POWTRAN technology company My future ,drive and control Performing motor auto-turning to get the motor parameters Automaticall
Service center of POWTRAN technology company My future ,drive and control 4. The time of auto-turning also depend on the( F0.13,F0.14) acceleration
Service center of POWTRAN technology company My future ,drive and control F0.00 Control Mode Sensor feedback close loop vector control 1 b0.27 mo
Service center of POWTRAN technology company My future ,drive and control 9. Apply the braking unit and braking resistor . The HP of 22kW of 220V and
Service center of POWTRAN technology company My future ,drive and control 10.1. Operating the VFD with keyboard Frequency setting F0.03=4 (keyboa
Service center of POWTRAN technology company My future ,drive and control 1.The introduction of new generation of PI9000 of POWTRAN Technology. The P
Service center of POWTRAN technology company My future ,drive and control 10.2 Operating Forward and reverse terminal for JOG running FJOG/RJOG r
Service center of POWTRAN technology company My future ,drive and control 10.3.1.Operating VFD by I/O terminals board. (I/O) terminals for connecting
Service center of POWTRAN technology company My future ,drive and control +10V GND external potentiometer for giving 0-10V input signal Push button
Service center of POWTRAN technology company My future ,drive and control 10.3.3. FWD and REV running controlled by I/O terminal . 1. Wring F0.11
Service center of POWTRAN technology company My future ,drive and control 10.3.5. three line control mode F0.11 command source selection 1:Terminal
Service center of POWTRAN technology company My future ,drive and control 11. Frequency setting with external potentiometer (Variable resistor) F0.1
Service center of POWTRAN technology company My future ,drive and control 12. Frequency setting by analog current (AI2) Parameters setting JP4 jumper
Service center of POWTRAN technology company My future ,drive and control 13.Employ output analog signal for monitoring current ,frequency ,speed e
Service center of POWTRAN technology company My future ,drive and control 14. Multi-speed applying with I/O interface terminal CODE Description Ran
Service center of POWTRAN technology company My future ,drive and control 15.Frequency UP and Down controlled by I/O interface terminal board 1.Plea
Service center of POWTRAN technology company My future ,drive and control 2. The new generation of PI9000 has following feature . Input/output termi
Service center of POWTRAN technology company My future ,drive and control 16.1.Application of multi-function output .(1) alarm output CODE Descripti
Service center of POWTRAN technology company My future ,drive and control 16.2.Application of multi-function output 2. ( frequency arrival and frequ
Service center of POWTRAN technology company My future ,drive and control negative action, when Δ>0 is positive, frequency rises and when Δ<0 is nega
Service center of POWTRAN technology company My future ,drive and control 17.2.PID control for constant pressure water supply -electrical diagram ( 0
Service center of POWTRAN technology company My future ,drive and control PID control for constant pressure water supply Parameters setting F0.00
Service center of POWTRAN technology company My future ,drive and control . Suggestion : 1.Check the direction of running . Press “FWD” for 1 sec ,i
Service center of POWTRAN technology company My future ,drive and control 18. PI9000 apply in air compressor retrofitting with PID control function.
Service center of POWTRAN technology company My future ,drive and control Wirings of electrical diagram with 0-20mA type of pressure transmitter Pre
Service center of POWTRAN technology company My future ,drive and control Wirings of electrical diagram with 0-10V type pressure transmitter
Service center of POWTRAN technology company My future ,drive and control Parameters setting table F0.00 Control mode 2:V/F 2 F0.11 command sou
Service center of POWTRAN technology company My future ,drive and control 3. Installation of PI9000 procedure : Install show picture -1
Service center of POWTRAN technology company My future ,drive and control 19.Application of PI9000 series inverters in crane Forward Reverse Low
Service center of POWTRAN technology company My future ,drive and control DI1 – lift up the load DI2 – Down the load DI3- MSS1 for low speed runni
Service center of POWTRAN technology company My future ,drive and control 1. Must perform motor auto-turning first when apply the vector control mo
Service center of POWTRAN technology company My future ,drive and control CODE Description of Code Range of setting Refer. value F0.00 Control mo
Service center of POWTRAN technology company My future ,drive and control 20. Fault Diagnosis PI9000 inverter has a number of warning information and
Service center of POWTRAN technology company My future ,drive and control 21. VFD RS232 communication with PC I-1-3 Protocol description PI9000 ser
Service center of POWTRAN technology company My future ,drive and control Communication data structure PI9000 series inverter's Modbus protocol
Service center of POWTRAN technology company My future ,drive and control
Service center of POWTRAN technology company My future ,drive and control 1.Soft setting: PC com port com1,inverter Baud rate 9600, Data format, no
Service center of POWTRAN technology company My future ,drive and control F0.11 Command source selection 2.Communications command control F9.00 Ba
Service center of POWTRAN technology company My future ,drive and control Install show picture -2
Service center of POWTRAN technology company My future ,drive and control
Service center of POWTRAN technology company My future ,drive and control 5. Command Code: 06H, write a word. For example: Write 5000(1388H) into the
Service center of POWTRAN technology company My future ,drive and control keyboard Main Terminal cover I/O control terminal Front cover Power on inve
Service center of POWTRAN technology company My future ,drive and control 4.Examples of connections between the Inverter typical peripheral devices a
Service center of POWTRAN technology company My future ,drive and control 5.Keyboard operating instruction._1 The operator interface provides a m
Service center of POWTRAN technology company My future ,drive and control 5.Keyboard operating instruction. _2 1.The first menu F0 2.The second menu